Microtest MICROSCANNER Specifikace Strana 10

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 28
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 9
MicroScanner Pro
Users Manual
6
Operating Mode
MODE
Press MODE to select the desired test. The available
modes are:
WIREMAP
OFFICE IDENTIFIER
LENGTH
TONER
Calibration Mode
MODE
+
ON
OFF
Turn the MICROSCANNER PRO OFF, then hold the MODE
key down while pressing the ON key to start Calibrate
mode.
Use M
ICROSCANNER PRO to calibrate cable lengths of
more than 50 feet (15 meters) and up to 1500 feet (457
meters).
Setting the NVP percentage
Once in Calibrate Mode, the default NVP (Nominal
Velocity of Propagation) will be displayed followed by
the overall cable length. The cable length is measured
with the currently stored NVP.
NVP is the measure of how fast a signal travels down a
cable compared to the speed of light. The result will be
represented as a percentage of the speed of light. For
an accurate length test, the NVP must be set correctly.
aue01f.eps
Zobrazit stránku 9
1 2 ... 5 6 7 8 9 10 11 12 13 14 15 ... 27 28

Komentáře k této Příručce

Žádné komentáře